| Microprocessor |
| Supports up to 2 microprocessors |
Intel® Xeon® with 800 MHz system bus at 3.20 GHz, 1MB L2 cache or faster |
| Chipset |
Intel® E7520 |
| Memory |
| Four double data rate (DDR2) |
| Memory Capacity |
Support for 512 MB to 8 GB |
| DIMM Sizes |
256 MB, 512 MB, 1 GB, 2 GB |
| Memory Type |
2-way interleaved DDR2-400, PC3200, ECC SDRAM registered DIMMs only |
| Drives |
| Support for up to two internal 2.5-inch hard disk drives |
| Support for up to two 3.5" Ultra320 SCSI hot-swap hard disk drives (80-pin, SCA-2 connectors). Maximum data transfer: 320MB/sec on each Ultra 320 LVD channel. Supports RAID-1 or RAID-1E |
| Size |
| Height |
24.5 cm (9.7 inches) |
| Depth |
44.6 cm (17.6 inches) |
| Width |
2.9 cm (1.14 inches) |
| Maximum weight |
6.8 kg (15 lbs.) |
| Integrated Functions |
| Two Gigabit Ethernet controllers support full duplex, Wake on LAN®, teaming and failover |
| ATI Rage 7000M video controller |
| Local service processor provides interface for communication with the Intel® Server Blade Chassis and the management module, system and environmental monitoring, event recording and alert capability |
| Light-Guided Diagnostics (LED lights indicate failing component) Flash-based embedded diagnostics |
| USB buses for communication with keyboard, mouse, diskette drive, and CD-ROM drive1 |
| Front Panel Buttons |
Keyboard/ mouse/ video |
This button is for associating the keyboard port, mouse port, and video port with this blade server; the LED on this button flashes while the request is being processed, then is steady when ownership has been transferred to the blade server |
| Power Control Button |
This button is located behind the control panel door; press this button to manually turn the blade server on or off |
| Front Panel LEDs |
| Blade-error LED |
When this amber LED is lit, it indicates that a system error has occurred in the blade server |
| Information LED |
When this amber LED is lit, it indicates that information about a system error for the blade server has been placed in the system Error log |
| Location LED |
When this blue LED is lit, it has been turned on remotely by the system administrator to aid in visually locating the blade server; the location LED on the SBCE unit will be on as well |
| Activity LED |
When this green LED is lit, it indicates that there is hard-disk-drive or network activity |
| Power-on LED |
This green LED indicates the power status of the blade server in the following manner:
Flashing rapidlyâthe service processor on the blade server is handshaking with the SBCE management module
Flashing slowlyâthe blade server has AC power but is not turned on
Steadyâthe blade server has AC power and is turned on |
|
 |
| Input/Output |
| Power, cooling, removable-media drives, external ports, and advanced system management are provided by the Intel® Server Chassis SBCE. |
| Environment |
| Air Temperature |
Operating (system): 10°C to 35°C (50°F to 95°F); 0 to 914m (2998.69 ft) altitude Operating (system): 10°C to 32°C (50°F to 89.6°F); 914m to 2134m (2998.69 to 7000 ft.ft) altitude Non-operating (system): â40° to +60°C (-40° to +140°F) |
| Humidity |
Operating: 8% to 80% Non-operating: 5% to 80% |
| Electrical Input |
| Input Voltage |
12 V dc |
| Safety Compliance |
| USA |
UL 60950 â 3rd Edition/CSA 22.2. No. 60950 |
| Canada |
cUL certified â 3rd Edition/CSA 22.2. No. 60950- for Canada (product bea the single cUL mark for U.S. and Canada) |
| Europe |
Low Voltage Directive, 73/23/EEC TUV/GS to EN60950 2nd Edition with Amendments, A1 = A2 + A3 + A4 |
| International |
TUV/CB to IEC 60950 3rd Edition TUV/CB - EN60 950 2nd Edition + Amd 1-4 TUV/CB - EMKO-TSE (74-SEC) 207/94 |
| Australian/New Zealand |
CB Report to IEC 60950, 3rd Edition plus international deviation |
 |
| Electromagnetic Compatibility (EMC) |
| USA |
FCC CFR 47 Part 2 and 15, Verified Class A Limit |
| Canada |
IC ICES-003 Class A Limit |
| Europe |
EMC Directive, 89/336/EEC
EN55022, Class A Limit, Radiated & Conducted Emissions
EN55024 ITE Specific Immunity Standard
EN61000-4-2 ESD Immunity (Level 2 Contact Discharge, Level 3 Air Discharge)
EN61000-4-3 Radiated Immunity (Level 2)
EN61000-4-4 Electrical Fast Transient (Level 2)
EN61000-4-5 AC Surge
EN61000-4-6 Conducted RF
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-11 Voltage Dips and Interrupts
EN61000-3-2 Limit for Harmonic Current Emissions
EN61000-3-3 Voltage Flicker |
| Japan |
VCCI Class A ITE (CISPR 22, Class A Limit) IEC 1000-3-2 Limit for Harmonic Current Emissions |
| Australian/New Zealand |
AS/NZS 3548, Class A Limit |
| Taiwan |
BSMI Approval |
| Korea |
RRL Approval |
|