Bladeform SM-7140B
At twice the density of 1U servers, the Bladeform Blade Server Platform and Xeon Server Blades offer the density, power and manageability required by the enterprise data centers and high performance computing clusters of today. This Xeon Blade Server's balance of performance, density, modularity, and economy squeezes the maximum processing power from a given space while reducing administration costs associated with provisioning, management, and maintenance.

Please see our Bladeform Blade Server System.
   
Product Highlights Technical Specs Technical Support
SM-7140B Chassis SM-B290 Compute Blade Chassis Management Module
Fibre Channel Switch Fibre Channel Expansion Card  
 

Media Tray (on front)

Diskette drive 1.44 MB
CD-ROM drive IDE
Universal Serial Bus (USB) v1.1 port
Front system LED panel

Module Bays (on rear)

Four hot-swap 220-volt power-module bays
Two hot-plug management module bays
Four hot-plug switch-module bays
Two hot-swap blower bays

Blade Bays (on front)

14 hot-plug blade bays

Redundant Cooling

Two redundant variable-speed hot-swap blowers, 325 cubic ft per min (CFM), front to back airflow

Front Panel LEDs

Power-on LED When this green LED is lit, power is present to the chassis unit
Location LED When this blue LED is lit or flashing, it has been turned on by the system administrator, to aid in visually locating the chassis unit.
Over-temperature LED When this amber LED is lit, the temperature in the chassis unit exceeds the temp limits or a blade server reports an over-temp condition
Information LED When this amber LED is lit, a noncritical event has occurred that requires attention
System-error LED When this amber LED is lit, it indicates that a system error has occurred

Power Modules

Standard Two 2000-watt or greater (200-240VAC) hot-swap power modules; both power modules provide redundancy to each other
Maximum Four:
Power modules 1 and 2 supply 12V to all switch and management modules and to blade bays 1 through 6
Power modules 3 and 4 supply 12V to blade bays 7 through 14
Power modules 1 and 2 provide redundancy to each other
Power modules 3 and 4 provide redundancy to each other

Switch Modules

Standard Standard
Maximum Two hot-plug 1 Gbit Ethernet four-port switch modules and two hot-plug switch modules of another network-communication standard, such as Fibre Channel

Management Module

Redundant hot-plug management modules provide the following features:

System Management functions for the SCBE system
Video Port Analog
Keyboard Port PS2
Mouse PS2
Remote Management Connection 10/100 Mb Ethernet

Upgradeable Microcode

Management Module Firmware
Ethernet Switch Module Firmware
Blade Server Service Processor Firmware

Security Features

Remote Connection Login password
Remote Management Access Secure socket layer (SSL) security
  

Size

Height 304.2mm (12 in. or 7U)
Depth 711.2mm (28")
Width 444 mm (17.5")
Weight 124.73 kg. (275 lbs.) fully configured with modules and blades
44.91 kg. (99 lbs.) fully configured without blades

Acoustical Noise Emissions

Without Acoustics Module Option Sound power, idle: 7.4 bels maximum
Sound power, operating: 7.4 bels maximum
With Acoustics Module Option Sound power, idle: 6.9 bels maximum
Sound power, operating: 6.9 bels maximum

Environment

Air Temperature Operating (system): 10°C to 35°C (50°F to 95°F); 0 to 914m (2998.69 ft) altitude
Operating (system): 10°C to 32°C (50°F to 89.6°F); 914m to 2134m (2998.69 to 7000 ft.) altitude
Non-operating (system): -40° to +60°C (-40° to +140°F)
Humidity Operating: 8% to 80%
Non-operating: 8% to 80%

Electrical Input

Sine-wave input (50-60Hz single phase) required Minimum: 200 volts AC
Maximum: 240 volts AC

Heat Output

Approximate Heat Output (BTUs per hour) Minimum configuration: 1365 BTU/hour (400 watts)
Maximum configuration: 9622 BTU/hour (2860 watts)

Safety Compliance

USA UL 60950 – 3rd Edition/CSA 22.2. No. 60950
Canada cUL certified – 3rd Edition/CSA 22.2. No. 60950- for Canada (product bea the single cUL mark for U.S. and Canada)
Europe Low Voltage Directive, 73/23/EEC
TUV/GS to EN60950 2nd Edition with Amendments, A1 = A2 + A3 + A4
International TUV/CB to IEC 60950 3rd Edition
TUV/CB – EN60 950 2nd Edition + Amd 1–4
TUV/CB – EMKO-TSE (74-SEC) 207/94
Australian/New Zealand CB Report to IEC 60950, 3rd Edition plus international deviation

Electromagnetic Compatibility (EMC)

USA FCC CFR 47 Part 2 and 15, Verified Class A Limit
Canada IC ICES-003 Class A Limit
Europe EMC Directive, 89/336/EEC
EN55022, Class A Limit, Radiated & Conducted Emissions
EN55024 ITE Specific Immunity Standard
EN61000-4-2 ESD Immunity (Level 2 Contact Discharge, Level 3 Air Discharge)
EN61000-4-3 Radiated Immunity (Level 2)
EN61000-4-4 Electrical Fast Transient (Level 2)
EN61000-4-5 AC Surge
EN61000-4-6 Conducted RF
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-11 Voltage Dips and Interrupts
EN61000-3-2 Limit for Harmonic Current Emissions
EN61000-3-3 Voltage Flicker
Japan VCCI Class A ITE (CISPR 22, Class A Limit)
IEC 1000-3-2 Limit for Harmonic Current Emissions
Australian/New Zealand CB Report to IEC 60950, 3rd Edition plus international deviation
Taiwan BSMI Approval
Korea RRL Approval
Russia GOST Approved
International CISPR 22, Class A Limit
 

Microprocessor

Supports up to 2 microprocessors Two Dual-Core Intel® Xeon® with 1066/1333 MHz system bus
Chipset Intel® 5000P Series

Memory

Memory Capacity Support for 1GB to 16GB
DIMM Sizes 256MB, 512MB, 1GB, 2GB
Memory Type 2-way interleaved DDR2 ECC Fully Buffered DIMM

Drives

Two small form factor (SFF, 2.5") Serial Attached SCSI (SAS) hard disk drive bays

Size

Height 24.5 cm (9.7 inches)
Depth 44.6 cm (17.6 inches)
Width 2.9 cm (1.14 inches)
Maximum weight 5.4 kg (12 lbs.)

Integrated Functions

Two onboard Gigabit Ethernet controllers support teaming, failover, Wake on LAN, Serial over LAN (SOL), and TCP/IP Offload Engine (TOE); optional I/O and Memory Expansion Module has an additional Gigabit Ethernet controller with two Ethernet ports

ATI RN-50 video controller

Local service processor provides interface for communication with the Intel® Server Blade Chassis and the management module, system and environmental monitoring, event recording and alert capability

Light-Guided Diagnostics (LED lights indicate failing component) Flash-based embedded diagnostics

USB buses for communication with keyboard, mouse, diskette drive, and CD-ROM drive1

Front Panel Buttons

Keyboard/
mouse/
video
This button is for associating the keyboard port, mouse port, and video port with this blade server; the LED on this button flashes while the request is being processed, then is steady when ownership has been transferred to the blade server
Power Control Button This button is located behind the control panel door; press this button to manually turn the blade server on or off
Media Tray Button This button is for associating the media tray with this blade server; the LED on this button flashes while the request is being processed, then is steady when ownership has been transferred to the blade server
  

Front Panel LEDs

Blade-error LED When this amber LED is lit, it indicates that a system error has occurred in the blade server
Information LED When this amber LED is lit, it indicates that information about a system error for the blade server has been placed in the system Error log
Location LED When this blue LED is lit, it has been turned on remotely by the system administrator to aid in visually locating the blade server; the location LED on the chassis unit will be on as well
Activity LED When this green LED is lit, it indicates that there is hard-disk-drive or network activity
Power-on LED This green LED indicates the power status of the blade server in the following manner:
• Flashing rapidly – the service processor on the blade server is handshaking with the chassis management module
• Flashing slowly – the blade server has AC power but is not turned on
• Steady – the blade server has AC power and is turned on

Input/Output

Power, cooling, removable-media drives, external ports, and advanced system management are provided by the Blade Server Chassis.

Environment

Air Temperature Operating (system): 10°C to 35°C (50°F to 95°F); 0 to 914m (2998.69 ft) altitude
Operating (system): 10°C to 32°C (50°F to 89.6°F); 914m to 2134m (2998.69 to 7000 ft.ft) altitude
Non-operating (system): -40° to +60°C (-40° to +140°F)
Humidity Operating: 8% to 80%
Non-operating: 5% to 80%

Electrical Input

Input Voltage 12 V dc

Safety Compliance

United States/Canada UL 60950 – CSA 60950–1
Europe EN60950-1, CE – Low Voltage Directive 73/23/EEE
International IEC60950-1, CB Certificate &Report, IEC6095-1
Russia GOST R 50377–92 – License

Electromagnetic Compatibility (EMC)

United States/Canada FCC/ICES-003 – Emissions (United States/Canada) Verification
Europe EN55022 – Emissions
EN55024 – Immunity
EN61000-3-2 – Harmonics
EN61000-3-3 Voltage Flicker
ECE – EMC Directive 89/336/EEC
Japan VCCI Emissionss
Australian/New Zealand AS/NZS 3548 Emissions
Taiwan BSMI CNS13438 Emissions
Korea RRL MIC Notice No. 1997–41 (EMC) & 1997–42 (EMI)
Russia GOST R 29216–91 Emissions
GOST R 50628–95 Immunity
 

Chassis Management Module Features

Remote, out-of-band management Manage all compute blades in a consistent manner irrespective of what Operating system is installed on the server or what state the server is in (Pre-boot, Post-boot or failed).
Integrated KVM switch The built-in KVM switch provides full text and graphical access to any blade server console.
Emergency management access over LAN The Serial over LAN1 feature redirects serial traffic from any blade to any management console over the network. This allows remote problem diagnosis in the event of system failures.
Upward integration into Enterprise management consoles SNMP agents on the management module allow monitoring and control of the chassis and server blades from any enterprise management console on the network.
Intel® Active Air Flow Control Automatically controls the speed of the fan based on thermal sensors in the chassis.
Intel® Light-Guided Diagnostics Quickly resolve failures via the use of a series of LEDs on the blade server.
 

Fibre Channel Protocols

FC-PH version 4.3, FC-PH-2, FC-PH-3, FC-AL version 4.5, FC-AL-2 Rev 7.0, FC-FLA, FC-GS-3, FC-FG, FC-PLDA, FC-Tape, FC-VI, FC-SW-2, Fibre Channel Element MIB RFC 2837, and Fibre Alliance MIB version 4.0.

Fibre Channel service classes Class 2 and class 3
Operation modes Fibre Channel class 2 and class 3, connectionless.
External port type Generic loop port (GL_port)
Internal port type Fabric port (F_port)
Port characteristics External ports are automatically detected and self configuring
Number of Fibre Channel ports 2 external ports and 14 internal ports
Scalability 239 switches maximum depending on your configuration
Maximum number of user ports 475,000 ports
Buffer credits 12 buffer credits per port
Media type Small form-factor pluggable (SFP) module
Fabric port speed 1.0625 or 2.125 Gbps (gigabits per second)
Maximum frame size 2148 bytes (2112 byte payload)
System processor Geode SC1200
Fabric latency Less than 0.5 µsec
Fabric point-to-point bandwidth 2 Gbps or 4 Gbps at full duplex
Fabric aggregate bandwidth 64 Gbps at full duplex
Nonblocking architecture to prevent latency  

Switch Maintainability

Diagnosis Power-on self-test (POST) is performed on all functional components except the SFP module. Port operational tests include internal, external, and online tests.
User interface LED indicators

Fabric management

Management Methods Fibre Channel Module Manager (SAN Utility Application)
Telnet and command line interface (CLI)
Switch SNMP Agent Enables a network management workstation to receive configuration values, traffic information, and Fibre Channel failure data through SNMP and the Ethernet interface.

Dimensions

Width 112 mm (4.41 in.)
Height 29 mm (1.14 in.)
Depth 260.3 mm (10.25 in.)
Weight 2 lb

Environmental

Temperature and Altitude Operating: 5°C to 40°C (41°F to 104°F) at an altitude of 0 to 3,048 m (0 to 10,000 ft.)
Non-operating: 40°C to 65°C (40°F to 149°F) at an altitude of 0 to 15,240 m (0 to 50,000 ft.)
Humidity Operating: 8% to 80%, noncondensing
Non-operating: 5% to 80%, noncondensing

Switch Regulatory Certifications

Electrical Power source loading: 3.75 amps maximum at 12V dc
Heat output: 45 watts maximum
Operating voltage: 12V dc
Circuit protection: Internally fused
  

Safety Standards

USA: UL 60950 3rd Edition/CSA 22.2. No. 60950
Canada: cUL certified 3rd Edition/CSA 22.2. No. 60950- for Canada (product bears the single cUL mark for U.S. and Canada)
Europe: Low Voltage Directive, 73/23/EEC
TUV/GS to EN60950 2nd Edition with Amendments, A1 = A2 + A3 + A4
International: TUV/CB to IEC 60950 3rd Edition
TUV/CB – EN60 950 2nd Edition + Amd 1–4
TUV/CB – EMKO-TSE (74-SEC) 207/94
Australian/New Zealand: CB Report to IEC 60950, 3rd Edition plus international deviations

Emissions Standards

USA: FCC CFR 47 Part 2 and 15, Verified Class A Limit
Canada: IC ICES-003 Class A Limit
Europe: EMC Directive, 89/336/EEC
EN55022, Class A Limit, Radiated & Conducted EmissionsEN55024 ITE Specific Immunity Standard
EN61000-4-2 ESD Immunity (Level 2 Contact Discharge, Level 3 Air Discharge)
EN61000-4-3 Radiated Immunity (Level 2)
EN61000-4-4 Electrical Fast Transient (Level 2)
EN61000-4-5 AC Surge
EN61000-4-6 Conducted RF
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-11 Voltage Dips and Interrupts
EN61000-3-2 Limit for Harmonic Current Emissions
EN61000-3-3 Voltage Flicker
Japan: VCCI Class A ITE (CISPR 22, Class A Limit)
IEC 1000-3-2 Limit for Harmonic Current Emissions
Australia/New Zealand: AS/NZS 3548, Class A Limit
Taiwan: BSMI Approval
Korea: RRL Approval

Shortwave Laser SFP Module at 1 Gbps and multi-mode SFP module at 2 Gbps:

Connector LC-LC
Color coding Beige or black exposed connector surfaces
Cable Fibre Channel 100-M6-SN-I (50 µm multimode)
Wavelength 830 to 860 nm
Transmit power 10 dBm minimum
Receiver sensitivity 16 dBm average
Distance 500 meters maximum using 50 micronfiber
300 meters maximum using 62.5 micron fiber
Safety DHHS 21 CFR(J), IEC 825–1 CENCELEC EN 60825–1, VDE

Longwave Laser SFP Module at 1 Gbps and multi-mode SFP module at 2 Gbps:

Connector LC-LC Fibre Channel cable
Color coding Blue exposed connector surfaces
Cable Fibre Channel 100SM-LC-L (9 µm single mode)
Wavelength 1270 through 13.5 nm
Transmit power 10 dBm minimum
Receiver sensitivity 20 dBm average
Distance 2 meters to 10 kilometers
Safety DHHS 21 CFR(J), IEDC 825–1 CENELEC
EN 60825–1, VDE
 

Expansion card bus

  • Supports subset of PCI local bus specification, revision 2.2 and the PCI-X specification 1.0a

PCI/PCI-X signaling environment

  • Supports 3.3 V only

PCI/PCI-X transfer rate

  • The burst transfer rate is based on the input clock speed multiplied by the number of bytes (8)
  • PCI – 66 = 525 MB per second
  • PCI-X – 100 = 800 MB per second

Fibre Channel Specifications

  • Bus transfer rate: 200 MB per second Specifications maximum at half-duplex and 400 MB per second maximum at full-duplex
  • Support for both FCP-SCSI and IP protocols
  • Support for point-to-point fabric connection: F-Port Fabric Login
  • Support for FCAL public loop profile: FL-Port Login
  • Support for Fibre Channel services class 2 and 3
  • Support for FCP SCSI initiator and target operation
  • Support for full-duplex operation
  • Copper interface ac coupled

Processor

  • Single-chip design with two completely independent 2 Gb serial Fibre Channel ports. Each port provides:
    • RISC processor
    • Integrated serializer/deserializer
    • Receive direct memory access (DMA) sequencer
    • Frame buffer
    • Five-channel DMA controller

Host data transfer

  • 64-bit, 100 MHz bus-master DMA data transfers to 800 MB per second

RAM

  • 512 KB sync burst SRAM per channel supporting parity protection

BIOS ROM

  • BIOS ROM 128 KB of flash memory (the flash is field programmable)

NVRAM

  • NVRAM 256 bytes, field programmable

Onboard DMA

  • Five-channel DMA controller for each port: transmit, receive, command, auto-request, and auto-response

Frame buffer FIFO

  • Integrated 4 KB transmit and 6 KB receive frame buffer FIFO for each data channel

Connectors (internal only)

  • Board-to-board Molex HSM type for serial interfaces
  • 200 pin board-to-board for PCI-X interface

Dimensions

  • Approximately 9.35 cm x 13.14 cm (3.683 in. x 5.275 in.)

Operating power

  • Less than 12 watts
Rackform Rackmount Servers
Bladeform Blade Servers
Storform Storage
Hyperform HPC
What's New
Special Offers
Clearance Items
1U Servers
2U Servers
3U & Larger Servers
1U Twin Servers
Hyperform Clusters
Hyperform ROCKS+
Virtualization Products
Rackform Expedited Prebuilt
Racks & Accessories
Rackmount LCDs
Sliding Rail Kits
Support Brackets
Spares Kits
Warranties
Support & Downloads
Sustainable Computing
Library
News & Press Releases
Careers
Sponsorships & Affiliations
Discontinued Servers
About Us
Contact Us