RAID
- Hardware RAID5 & RAID6
- Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID, and JBOD
- RAID Migration
- Configurable stripe size and write policy per array
- Multiple Global, Dedicated, & Enclosure-specific hot-spares
- Intelligent Drive Handling:
- In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
|
Host Interface
- 4 SAS wide ports
- 12Gbps bandwidth (half duplex) per port
- Concurrent I/O commands
- Tagged command queuing up to 1024
- Max. command queue up to 1024
- Fault-tolerant host links with the EonPath multi-pathing software
- Included cables:
- D601R – 2x Mini-SAS-to-Mini-SAS SFF-8088 1.2m cables
|
Drive Interface
- 12 3.0Gbps SAS/SATA-II, hot-swappable drive trays
- Accommodates 1-inch pitch, 3.5-inch SAS or SATA-II (3Gbps) disk drives
- S.M.A.R.T. and NCQ support
- Automatic bad-sector reassignment
- Dedicated bandwidth to each connected drive
- In-band enclosure service through the expansion links from expansion enclosures
- Path redundancy to disk drives via edge expanders and expanders on JBOD controllers through separate SAS domains
- MUX kits with port selectors for dual-controller access to SATA drives
|
Management
- COM1 serial port for local access to firmware-embedded utility
- COM2 for UPS connection
- Automated cache flush and caching mode operation per enclosure status
- GUI, Telnet, and SSH system monitoring via Ethernet
- Browser-based or Java-based RAIDWatch manager software
- Firmware-embedded manager via RS-232C (audio jack) that is platform independent
- Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
- LCD keypad panel for monitoring and access to all configuration options
- Variable logical drive options per DIMM size
- Module status LED indicators:
- Two (2) per drive tray
- Seven (7) per controller module
- One (1) per power supply unit
- One (1) per BBU module
- Two (2) per cooling module
- Presence detection & thermal sensors via I2C bus
|
|
|
System Components
- High density, smartly managed 2U enclosure
- Dual redundant RAID controller
- One DIMM module with capacities from 512MB to 2GB
- Redundant, hot-swappable 530W power supply units
- Redundant, dual-speed cooling modules
- 12 hot-swappable drive trays
- 2 forearm handles
- Li-Ion battery backup unit (BBU), life expectancy and charge level aware
|
Power Supply Module
| Redundant hot-swappable power supplies with PFC |
| Input |
- 100VAC at 9A, 240VAC at 4.5A with PFC (auto-switching) 47 to 63Hz
|
| Output |
- Maximum output: 530 Watts
- +12V – 43A max
- +5V – 25A max
|
Cooling Module
| Redundant dual-thermal-fan cooling modules |
- Maximum air flow: 90CFM (high speed); 70.7CFM (low speed)
|
Environmental Specifications
| Operating temperature |
- 5º to 40ºC (35°C if battery is applied)
|
| Non-operating temperature |
|
| Relative humidity |
|
| Operating altitude |
- Operating: 0 to 12,000 ft
|
Dimensions
| Package: |
- 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
|
| Chassis without handles: |
- 446(W) x 88(H) x 498(D) mm (17.56W x 3.46H x 19.6D inches)
|
| Chassis with handles: |
- 482 (W) x 88(H) x 516(D) mm (18.97W x 3.46H x 20.31D inches)
|
System Weight
|
- Net weight: 18.71kg (41.16 pounds)
- Gross weight: 25.9kg (56.98 pounds)
|
|